This standard is issued under the fixed designation D; the number 1 This test method is under the jurisdiction of ASTM Committee D18 on Soil and. All the Controls products ASTM D standard. Enter now!. ASTM D (Ultrasonic Crosshole Testing).pdf – Download as PDF File .pdf ), Text File .txt) or read online.

Author: Yotilar Kegis
Country: Azerbaijan
Language: English (Spanish)
Genre: Spiritual
Published (Last): 3 May 2018
Pages: 428
PDF File Size: 5.17 Mb
ePub File Size: 9.7 Mb
ISBN: 474-5-59022-960-1
Downloads: 9215
Price: Free* [*Free Regsitration Required]
Uploader: Shakakazahn

Link to Active This link will always route to the current Active version of the standard. No other units of measurement are included in this standard. How one applies the results obtained using this standard is beyond its scope. The data are used to confirm adequate concrete quality or identify zones of poor quality.

Accept and continue Learn more about the cookies we use and how to change your settings. Your basket is empty.

ASTM D6760 – 16

This method is most applicable when performed in tubes that are installed during construction. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program. The faster, easier way to work with standards.

Since the generated waves travel through the concrete around the access duct, unless a flaw is massive enough and very near to the access duct it may not be detected by this method. Active view current version of standard. Historical Version s – view previous versions of standard. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program.

  JACK LONDON BILY TESAK PDF

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. Testing should therefore be performed as soon as practical in order to avoid debonding issues.

No other units of measurement are included in this standard. Worldwide Standards We can source any standard from anywhere in the world.

D676 defects are detected, then further investigations should be made by excavation or coring the concrete as appropriate, or by other testing such as Test Method DD or Dand measures taken to remediate the structure if a defect is confirmed. Learn more about the cookies we use and how to change your settings. This method is most applicable when performed in tubes that are installed during construction.

Barrette, Bored pile, Crosshole sonic logging, Crosshole testing, Drilled shaft, Integrity test, Single hole ultrasonic testing, Ultrasonic logging, Ultrasonic testing.

Agencies that meet the criteria of Practice D are generally considered capable of competent and objective testing and inspection. Active view current version of standard Translated Ast, You may experience issues viewing this site in Internet Explorer 9, 10 or Please download Chrome or Firefox or view our browser tips.

qstm

ASTM D, Test equipment Controls

We use cookies to make our website easier to use and to better understand your needs. Click to learn more. The method does not give the exact type of defect for example, inclusion, honeycombing, lack of cement particles, etc.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

How one applies the results obtained using this standard is beyond its scope. Aatm method does not give the exact type of flaw for example, inclusion, honeycombing, lack of cement particles, etc.

Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results. This method can also be extended to diaphragm walls, barrettes, dams etc. Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  CAYIN SMP PRO4 PDF

You may find similar items within these categories by selecting from the choices below:. The method is limited primarily to testing the concrete between the access ducts and thus gives little information about the concrete outside the reinforcement cage to which the access ducts are attached when the tubes are attached to the inside of the reinforcement cage. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This method can also be extended to diaphragm walls, barrettes, dams etc. The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

This test can assess to the integrity of the concrete mainly in the area bounded by the access ducts, which means typically inside the reinforcement cage. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Find Similar Items This product falls into the following categories. Search all products by. Link to Active This link will always route to the current Active version of the standard.